2024/11/11 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:127 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2024/11/10 0.5784 1.01846 1.0334 00.4170 00.0000 00.0000 96.3100 02.0619 00.1487 00.0094 00.0120 00.0000 00.0026 00.0018 00.0012 00.0009 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2024/11/10 0.5689 1.00824 0.4083 01.0854 00.0000 00.0000 97.3670 01.0990 00.0363 00.0013 00.0024 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2024/11/10 0.5908 1.03536 0.7493 01.0067 00.0000 00.0000 93.4101 04.6360 00.1738 00.0069 00.0108 00.0000 00.0021 00.0016 00.0010 00.0007 00.0003 00.0000 CHANDLER ST DISCHARGE G 2024/11/10 0.5893 1.03367 0.7419 00.9771 00.0000 00.0000 93.6793 04.4344 00.1488 00.0061 00.0072 00.0000 00.0015 00.0011 00.0010 00.0007 00.0003 00.0000 FM 63 - Columbia GC @ 2 2024/11/08 0.5998 1.07306 0.1964 00.4287 00.0000 00.0000 91.3470 07.6549 00.3075 00.0202 00.0335 00.0000 00.0052 00.0023 00.0018 00.0013 00.0006 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.